Aktiv Normen | Herausgegeben: 01.10.2023

ČSN EN IEC 61400-21-2

Wind energy generation systems - Part 21-2: Measurement and assessment of electrical characteristics - Wind power plants

Verfügbare Sprachen: Englisch

Verfügbare Ausführung: Gedruckt

ab 47.80 EUR im E-Shop anzeigen

Detailinformationen

Bezeichnung: ČSN EN IEC 61400-21-2

Ausgabedatum: 01.10.2023

Seiten: 156

Land: Tschechische technische Norm

Wo ist es zu kaufen?

Erhältlich auf www.technormen.de

Annotation

This part of IEC 61400 defines and specifies the quantities that are determined to characterize the electrical characteristics of grid-connected power plants (PPs).
This document defines the measurement and test procedures for quantifying the electrical characteristics as basis for the verification of compliance of PPs, including:
- power quality aspects,
- steady state operation,
- dynamic response (undervoltage and overvoltage fault ride-through),
- disconnection from grid (grid protection),
- control performance.
This document defines a uniform functionality test and measurement procedure for the power plant controller (PPC), as a basis for the unit test of the power plant controller.
This document defines the procedures for assessing compliance with electrical connection requirements, including the aggregation methods for power quality aspects such as voltage variations, flicker, harmonics and interharmonics.
This document defines the procedures for measurement and fault recording, for example for the verification of power plant electrical simulation models in relation to undervoltage and overvoltage ride-through events.
These measurement procedures are valid for power plants, including the power plant controller and other connected equipment, necessary for the operation of the power plant. The measurement procedures are valid for any size of power plant connected to the point of connection (POC) at one connection point.
The procedures for assessing and verifying the compliance with grid connection requirements are valid for power plants in power systems with fixed frequency and a sufficient short-circuit power