Active standard | Published: 01/05/2025

ČSN EN ISO 16784-1

Corrosion of metals and alloys - Corrosion and fouling in industrial cooling water systems - Part 1: Guidelines and requirements for conducting pilot-scale evaluation of corrosion and fouling control additives for open recirculating cooling water systems

Available languages: English

Available design: Print design

from 13.90 EUR show on eshop

Detail information

Designation: ČSN EN ISO 16784-1

Publication date: 01/05/2025

Pages: 28

Country: Czech technical standard

Where to buy?

You can buy at www.mystandards.biz

Anotation

This document specifies general requirements and parameters for the pilot test evaluation of corrosion and scaling control additives in open recirculating cooling water systems. This document covers parameters including test unit design, operation, water quality and contamination. It also covers the design and operation of pilot test devices as well as parameters to be evaluated in pilot test units.
This document covers the criteria that are used in pilot scale testing programmes for selecting water treatment programmes for specific recirculating cooling water systems.
This document is only applicable to open recirculating cooling water systems. It does not apply to closed cooling systems and once-through cooling water systems.
This document applies only to systems that incorporate shell and tube heat exchangers with standard uncoated smooth tubes and cooling water on the tube side. This document does not apply to heat exchangers with shell-side water, plate and frame and/or spiral heat exchangers and other heat exchange devices. However, when the test conditions are properly set up to model the surface temperature and shear stress in more complex heat transfer devices, the test results can predict the results of operating heat exchangers of that design.
The test criteria established in this document are not intended to govern the type of bench and pilot scale testing normally carried out by water treatment companies as part of their proprietary product development programmes. However, water treatment companies can choose to use the criteria in this document as guidelines in the development of their own product development test procedures
Loading
Cookies Cookies

Potřebujeme Váš souhlas k využití jednotlivých dat, aby se Vám mimo jiné mohli ukazovat informace týkající se Vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.

Souhlas můžete odmítnout zde.

Zde máte možnost přizpůsobit si nastavení souborů cookies v souladu s vlastními preferencemi.

Potřebujeme Váš souhlas k využití jednotlivých dat, aby se Vám mimo jiné mohli ukazovat informace týkající se Vašich zájmů.