Anotácia

IEC 61526:2024+AMD1:2026 CSV applies to personal dosemeters with the following characteristics: a) They are worn on the trunk, close to the eye, or on the extremities. b) They measure the personal dose equivalents Hp(10), Hp(3), and Hp(0,07), from external X and gamma, neutron (not for Hp(3)), and beta radiations, and may measure the respective personal dose equivalent rates for the same radiations (for alarming purposes). c) They have a digital indication. This indication may or may not be attached. d) They have alarm functions for the personal dose equivalents or personal dose equivalent rates except for hybrid dosemeters. For hybrid dosemeters an alarm function for the personal dose equivalents shall be implemented in the associated readout system. This document specifies requirements for the dosemeter and, if supplied, for its associated readout system. This document specifies, for the dosemeters described above, general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and envi­ronmental characteristics. This edition includes the following significant technical changes with respect to the previous edition: a) Modification of the title; b) Inclusion of the measurement quantity for the dose in the lens of the eye, Hp(3); c) Inclusion of measurement quantity for dose in the skin and extremities, Hp(0,07); d) Inclusion of dosemeters between active and passive: "hybrid dosemeters"; e) Inclusion of software requirements; f) Harmonization of requirements for linearity to IEC 62387; g) Revised neutron energy response requirements.
Loading
Cookies Cookies

Potřebujeme Váš souhlas k využití jednotlivých dat, aby se Vám mimo jiné mohli ukazovat informace týkající se Vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.

Souhlas můžete odmítnout zde.

Zde máte možnost přizpůsobit si nastavení souborů cookies v souladu s vlastními preferencemi.

Potřebujeme Váš souhlas k využití jednotlivých dat, aby se Vám mimo jiné mohli ukazovat informace týkající se Vašich zájmů.