ISO/TS 21569-7:2022 img
Aktivní norma | Vydána: 05.12.2022

ISO/TS 21569-7:2022

Horizontal methods for molecular biomarker analysis — Methods of analysis for the detection of genetically modified organisms and derived products — Part 7: Real-time PCR based methods for the detection of CaMV and Agrobacterium Ti-plasmid derived DNA sequences
(Méthodes horizontales d´analyse moléculaire de biomarqueurs — Méthodes d´analyse pour la détection des organismes génétiquement modifiés et des produits dérivés — Partie 7: Méthodes par PCR en temps réel pour la détection des séquences ADN dérivées du plasmide Ti de la bactérie Agrobacterium et du CaMV (virus de la mosaique du chou-fleur))

Dostupné jazyky: Anglicky

Dostupné provedení: Elektronické PDF, Tištěné

od 2 087.00 CZK zobrazit na eshopu

Podrobné informace

Označení: ISO/TS 21569-7:2022

Datum vydání: 05.12.2022

Stran: 12

Země: Mezinárodní technická norma

Kde koupit?

Můžete zakoupit na eshop.normservis.cz

Anotace

Description / Abstract: This document specifies a procedure for the detection of a DNA sequence of the open reading frame five (ORF V) from cauliflower mosaic virus (CaMV) and a procedure for the detection of the DNA sequence of the nopaline synthase (nos) gene from tumour-inducing (Ti) plasmids of phytopathogenic Rhizobium radiobacter (formerly named Agrobacterium tumefaciens). The procedures can be used in the context of screening for genetically modified crop/plants and their derived products to further clarify a positive PCR result for a specific promoter or terminator of CaMV (P-35S, T-35S), or both, and the nos gene (P-nos, T-nos), respectively. The methods specified in this document will detect and identify naturally occurring CaMV or Rhizobium radiobacter (Ti plasmid) DNA, or both, if present in the sample in the absence of a genetically modified plant event containing the specified target sequences. Both methods are based on the real-time polymerase chain reaction (PCR) and are applicable for the analysis of DNA extracted from foodstuffs and other products such as feedstuffs and seeds/grains. The application of the methods requires the extraction of an adequate amount of amplifiable DNA from the relevant matrix. With appropriate calibration material, the CaMV ORF V or nos copy number, or both, can be estimated and compared, respectively, with the estimated copy number for the promoter (P-35S, P-nos) or the terminator (T-35S, T-nos) sequences, or both. Thereby, conclusions are possible about the presence of an unknown genetically modified organism (GMO) in addition to any detected CaMV DNA or Rhizobium radiobacter Ti plasmid DNA, or both, in a test sample.
Loading
Cookies Cookies

Potřebujeme Váš souhlas k využití jednotlivých dat, aby se Vám mimo jiné mohli ukazovat informace týkající se Vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.

Souhlas můžete odmítnout zde.

Zde máte možnost přizpůsobit si nastavení souborů cookies v souladu s vlastními preferencemi.

Potřebujeme Váš souhlas k využití jednotlivých dat, aby se Vám mimo jiné mohli ukazovat informace týkající se Vašich zájmů.