ISO 16200-2:2000 img
Aktivní norma | Vydána: 08.06.2000

ISO 16200-2:2000

Workplace air quality — Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography — Part 2: Diffusive sampling method
(Qualité de l´air des lieux de travail — Échantillonnage et analyse des composés organiques volatils par désorption au solvant/chromatographie en phase gazeuse — Partie 2: Méthode d´échantillonnage par diffusion)

Dostupné jazyky: Anglicky

Dostupné provedení: Elektronické PDF, Tištěné

od 235.20 USD zobrazit na eshopu

Podrobné informace

Označení: ISO 16200-2:2000

Datum vydání: 08.06.2000

Stran: 32

Země: Mezinárodní technická norma

Kde koupit?

Můžete zakoupit na eshop.normservis.cz

Anotace

Description / Abstract: This part of ISO 16200 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. This part of ISO 16200 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of devices and sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. NOTE Activated coconut shell charcoal is frequently used. Very polar compounds may require derivatization; very low boiling compounds will only be partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds will be fully retained by the sorbents, but may only be partially recovered. This part of ISO 16200 is valid for the measurement of airborne vapours of VOCs in a concentration range of approximately 1 mg/m3 to 1000 mg/m3 individual organic for an exposure time of 8 h. The upper limit of the useful range is set by the sorptive capacity of the sorbent used and, subject to dilution of the analysed solution, by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sampling devices or in the desorption solvent. Artefacts are typically sub-nanogram for activated charcoal, but higher levels of aromatic hydrocarbons have been noted in some batches.
Loading
Cookies Cookies

Potřebujeme Váš souhlas k využití jednotlivých dat, aby se Vám mimo jiné mohli ukazovat informace týkající se Vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.

Souhlas můžete odmítnout zde.

Zde máte možnost přizpůsobit si nastavení souborů cookies v souladu s vlastními preferencemi.

Potřebujeme Váš souhlas k využití jednotlivých dat, aby se Vám mimo jiné mohli ukazovat informace týkající se Vašich zájmů.